TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 5-3. Radio Receiver-Transmitter RT-980/’GRC-171 Performance Tests (Sheet 2 of 17)
CONTROL SETTINGS
OPERATION OF TEST AND OPERATION PERFORMANCE
STEP EQUIPMENT POINT OF TEST OF EQUIPMENT STANDARD
RECEIVER MAIN AUDIO (NARROW BAND) OUTPUT (Cont)
6 Connect distortion
analyzer and 600-ohm
load to RT-980/
GRC-171 AUDIO
OUTPUT 1 and 2
(A10A2J22-N/’S).
7 Set rf signal generator for Set REMOTE/LOCAL
rf output level 3
µ
V at switch to LOCAL,
225.000 MHz, 30% modu- PTT/CARRIER
lation at 1 kHz. TEST switch to PTT,
SQUELCH switch to
OFF and frequency
switches to
225.000 MHz.
8 Set distortion analyzer AUDIO OUTPUT Adjust RCV AUDIO 7.75 V rms.
FUNCTION control to (A10A2J22-N/S) level control to
VOLTMETER. obtain a main
audio output level
of 100 mW (7.75
V rms across
600-ohm load).
9 Increase rf signal Not more than 3 dB.
generator rf input level
to 1.0 V (into 50 ohms)
and determine increase
in audio output from that
measured in step 8.
RECEIVER SIGNAL-PLUS-NOISE TO NOISE RATIO
10 Set rf signal generator for
rf output level of 3.0 ,tV
at 225.000 MHz, 30%
modulation at 1 kHz. Ob-
serve distortion analyzer
meter. Set the level to
0 dB (some convenient
reference).
11 Set distortion analyzer
FUNCTION control to
DISTORTION and deter-
mine noise level of 1
kHz signal in dB.