AB Amps 980A Operations Instructions Page 119

  • Download
  • Add to my manuals
  • Print
  • Page
    / 218
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 118
TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 5-3. Radio Receiver-Transmitter RT-980/GRC-171 Performance Tests (Sheet 15 of 17)
CONTROL SETTINGS
OPERATION OF TEST AND OPERATION PERFORMANCE
STEP EQUIPMENT POINT OF TEST OF EQUIPMENT STANDARD
TRANSMITTER KEYING (Cont)
66 a. Adjust power supply TEST meter a. Observe the a. Power indication
for 6-V dc output and (A10A1M1) transmitter on TEST meter.
and connect power is keyed.
supply to RT-980/
GRC-171 VOLTAGE
LOOP input
(A10A2J22-X/Y).
b. Adjust power supply b. Observe the b. Power indication
for 26-V dc output transmitter is on TEST meter.
and connect power keyed.
supply to RT-980/
GRC-171 VOLTAGE
LOOP input
(A10A2J22-X/Y).
c. Adjust power supply c. Observe the c. Power indication
for 48-V dc output transmitter is on TEST meter.
and connect power keyed.
supply to RT-980/
GRC-171 VOLTAGE
LOOP input
(A10A2J22-X/Y).
d. Adjust power supply d. Observe the d. Power indication
for 100-V dc output transmitter is on TEST meter.
and connect power keyed.
supply to RT-980/
GRC-171 VOLTAGE
LOOP input
(A10A2J22-X/Y).
67 Adjust power supply to TEST meter Observe the Power indication on
current limit at 20 mA (A10A1M1) transmitter TEST meter.
and connect power sup- is keyed.
ply to RT-980/
GRC-171 CURRENT
LOOP input
(A10A2J22-V/W).
68 Disconnect power supply
from RT-980/GRC-171.
69 Connect audio oscillator TEST meter Observe the Power indication on
to RT-980/GRC-171 (A10A1M1) transmitter is TEST meter.
AUDIO LOOP input keyed.
(A10A2J22-T/U) and
adjust audio oscilla-
tor for 1000-Hz tone
at 0.245-V rms
output.