TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 5-3. Radio Receiver-Transmitter RT-980/GRC-171 Performance Tests (Sheet 17 of 17)
CONTROL SETTINGS
OPERATION OF TEST AND OPERATION PERFORMANCE
STEP EQUIPMENT POINT OF TEST OF EQUIPMENT STANDARD
RADIO RECEIVER-TRANSMITTER OPERATIONAL PERFORMANCE (Cont)
73 PLL OUT PLL OUT 0.5 to 1.5 V dc.
(Cont) (A10A1TP4)
PLL FAULT PLL FAULT 2.0 to 5.0 V dc.
(A10A1TP5)
PA FWD PA FWD 0.5 to 1.2 V dc.
(A10A1TP6)
PA REFL PA RE FL -0.3 to 0.3 V dc.
(A10A1TP7)
ALC ALC 0.5 to 2.5 V dc.
(A10A1TP8)
KEY KEY 0.05 to 0.5 V dc.
(A10A1TP9)
XMT AUDIO XMIT AUDIO Whistle or hum into 0.6 to 1.1 V rms.
(A10A1TP11) microphone.
RECT DC RECT DC 21 to 60 V dc.
(A10A1TP13)
74 Connect vom between SERVO + SERVO+ and SERVO-
SERVO + and GND and (A10A1TP1) to ground (in quiescent
SERVO - and GND test state) 0 to 6.5 V dc.
points on the GND
RT-980/GRC-171. (A10A1TP14)
SERVO -
(A10A1TP2)
75 Connect digital multi- Unkey transmitter.
meter to the following
RT-980/GRC-171 test
points and verify
readings:
RCV AUDIO RCV AUDIO 0.16 to 0.3 V rms.
(A10A1TP10)
IF AGC IF AGC -0.3 to -0.7 V dc.
(A10A1TP12)
76 Turn off and disconnect Place Radio Set
all test equipment from AN/GRC-171 in
RT-980/GRC-171. operational status
required.
5-23
Page view 120